ATAGO(·RÌX)ªº¦Û°Ê§é®g»öªº¾Þ§@¤è¦¡Â²³æ¡A¥B¨ã¦³ºë½T¡B´ú¶q­È¥i¥H«H¿àªº²£«~³]­p¯S©Ê¡C·í»P¶Ç²Î©Mªü¨©§é®g»ö¬Û¸û¡A¼Æ¦ì¤j¿Ã¹õªº³]­p±NÅý¨Ï¥ÎªÌ§ó®e©öŪ¨ú´ú¶q­È¡C

RX-α series

A Wide Selection to Meet
Every Measurement Need

RX-i series

The world's highest standard of technology now
available with touch screen.

IJºN«Ì¦¡¥þ¦Û°Ê¥x¦¡¼ÆÅã§é¥ú»ö RX-5000i-Plus

The most accurate refractometer in the world is now even more stylish, smart, and functional.
Featuring intuitive touch screen technology, the new RX-i series makes navigation and selection a breeze.
The RX-5000i-Plus measures with the same accuracy level as the RX-5000α-Plus - ±0.010% Brix and ±0.00002 nD.
The RX-i series come with newly added functions, such as USB flash drive and self-diagnosis capability.
This product comes standard with a two (2) year limited warranty against manufacturer's defects from the date of the original purchase. This warranty does not cover or apply to the touchscreen. The warranty period can be extended to three (3) years if the product is registered with ATAGO.


Enlargement
Quantity

>about the icons RS-232C Interface External temperature samples User scales can be inputted Measurement at a set temperature Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-5000i-Plus «¬¸¹ 3275
´ú¶q½d³ò Refractive index (nD) : 1.32422 to 1.58000
Brix : 0.000 to 100.000%
( 5 to 75°C ATC)
³Ì¤p«ü¥Ü­È Refractive index (nD) : 0.00001
Brix : 0.005%
Temperature: 0.01°C
´ú¶q·Ç½T«× Refractive index (nD) :
±0.00002
Brix : ±0.010%
Temperature control range 5.00 to 75.00°C
(No lower than 10¢XC below the ambient temperature and no higher than 55¢XC above the ambient temperature)
Repeatability Refractive index : ±0.00001 Brix : ±0.010% ¹q·½ AC100V to 240V, 50/60Hz
¹q¤O·l¯Ó 90VA ¤Ø¤o­«¶q 37×26×14cm, 6.6kg
(Main Unit only)
´ú¶q§Î¦¡ MODE-1:
Displays the measurement value once the sample reaches the target temperature.

MODE-2:
Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.

MODE-3:
The thermo-module can be turn off. Without temperature control, the measurement value is displayed in 4 seconds after the START key is pressed.

MODE-S:
Displays the measurement value once a certain level of sample stability is achieved.
¿é¥X²×ºÝ¾÷ • Printer (for ATAGO digital printers)
• Computer -USB
Warranty 2 years standard (3 years with product registration) excluding touchscreen
¿ï¥ó Software Refractosoft : Cat.No.3176
Digital Printer DP-63 : Cat.No.3118
Digital Printer DP-AD : Cat.No.3123
MAGIC™(metal) : RE-56180
MAGIC™(resin) : RE-56185
Flow cell attachment : RE-56172
10% ½©¿}·»²G (±0.01%) : RE-111001
20% ½©¿}·»²G (±0.01%) : RE-112001
30% ½©¿}·»²G (±0.01%) : RE-113001
40% ½©¿}·»²G (±0.02%) : RE-114002
50% ½©¿}·»²G (±0.02%) : RE-115002
* Calibration Certificate : Contact an ATAGO representative for details.
®ø¯Ó«~/¹s¥ó Printer paper (regular) for DP-63 : RE-8412
Printer paper (long-term storage)for DP-63 : RE-8414
Printer paper for DP-AD : RE-89403
Ribbon cassette for DP-AD : RE-89402
• Fan Filter Replacement : RE-58001
¤U¸ü«¬¿ý ( English only )
Go to the product search GO TOP

IJºN«Ì¦¡¥þ¦Û°Ê¥x¦¡¼ÆÅã§é¥ú»ö RX-5000i

The most accurate refractometer in the world is now even more stylish, smart, and functional.
Featuring intuitive touch screen technology, the new RX-i series makes navigation and selection a breeze.
The RX-5000i measures with the same accuracy level as the RX-5000α ±0.03% Brix and ±0.00004 nD.
The RX-i series come with newly added functions, such as USB flash drive and self-diagnosis capability.
This product comes standard with a two (2) year limited warranty against manufacturer's defects from the date of the original purchase. This warranty does not cover or apply to the touchscreen. The warranty period can be extended to three (3) years if the product is registered with ATAGO.


Enlargement
Quantity

>about the icons RS-232C Interface External temperature samples User scales can be inputted Measurement at a set temperature Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-5000i «¬¸¹ 3276
´ú¶q½d³ò Refractive index (nD) : 1.32422 to 1.58000
Brix : 0.00 to 100.00%
( 5 to 75°C ATC)
³Ì¤p«ü¥Ü­È Refractive index (nD) : 0.00001
Brix : 0.01%
Temperature: 0.01°C
´ú¶q·Ç½T«× Refractive index (nD) :
±0.00004
Brix : ±0.03%
Temperature control range 5.00 to 75.00¢XC
(No lower than 10¢XC below the ambient temperature and no higher than 55¢XC above the ambient temperature)
Repeatability Refractive index : ±0.00002
Brix : ±0.01%
¹q·½ AC100V to 240V, 50/60Hz
¹q¤O·l¯Ó 90VA ¤Ø¤o­«¶q 37×26×14cm, 6.6kg
(Main Unit only)
´ú¶q§Î¦¡ MODE-1:
Displays the measurement value once the sample reaches the target temperature.

MODE-2:
Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.

MODE-3:
The thermo-module can be turn off. Without temperature control, the measurement value is displayed in 4 seconds after the START key is pressed.

MODE-S:
Displays the measurement value once a certain level of sample stability is achieved.
¿é¥X²×ºÝ¾÷ • Printer (for ATAGO digital printers)
• Computer -USB
Warranty 2 years standard (3 years with product registration) excluding touchscreen
¿ï¥ó Software Refractosoft : Cat.No.3176
Digital Printer DP-63 : Cat.No.3118
Digital Printer DP-AD : Cat.No.3123
MAGIC™(metal) : RE-56180
MAGIC™ (resin) : RE-56185
Flow cell attachment : RE-56172
10% ½©¿}·»²G (±0.01%) : RE-111001
20% ½©¿}·»²G (±0.01%) : RE-112001
30% ½©¿}·»²G (±0.01%) : RE-113001
40% ½©¿}·»²G (±0.02%) : RE-114002
50% ½©¿}·»²G (±0.02%) : RE-115002
* Calibration Certificate : Contact an ATAGO representative for details.
®ø¯Ó«~/¹s¥ó Printer paper (regular) for DP-63 : RE-8412
Printer paper (long-term storage)for DP-63 : RE-8414
Printer paper for DP-AD : RE-89403
Ribbon cassette for DP-AD : RE-89402
• Fan Filter Replacement : RE-58001
¤U¸ü«¬¿ý ( English only )
Go to the product search GO TOP

IJºN«Ì¦¡¥þ¦Û°Ê¥x¦¡¼ÆÅã§é¥ú»ö RX-7000i

Featuring intuitive touch screen technology, the new RX-i series makes navigation and selection a breeze.
The RX-i series come with newly added functions, such as USB flash drive and self-diagnosis capability.
The RX-7000i features an even wider refractive index range than its predecessor.
This product comes standard with a two (2) year limited warranty against manufacturer's defects from the date of the original purchase. This warranty does not cover or apply to the touchscreen. The warranty period can be extended to three (3) years if the product is registered with ATAGO.


Enlargement
Quantity

>about the icons RS-232C Interface External temperature samples User scales can be inputted Measurement at a set temperature Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-7000i Cat.No. 3279
Measurement Range Refractive index (nD) : 1.32422 to 1.70000
Brix : 0.00 to 100.00%
( 5 to 75°C ATC )
Minimum indication Refractive index (nD) :
0.00001 (0.0001)*
Brix : 0.01% (0.1%)*
Temperature: 0.01°C
*Factory default setting
Measurement Accuracy
*Repeatability
Refractive index (nD) :
±0.0001
*±0.00005
Brix : ±0.1%
*±0.02%
[*1]
Temperature control range 5.00 to 75.00°C
(No lower than 10°C below the ambient temperature and no higher than 55°C above the ambient temperature)
Power Supply AC100V to 240V, 50/60Hz
Power consumption 90VA Dimensions & weight 37×26×14cm, 7.0kg
(Main Unit only)
Mode MODE-1:
Displays the measurement value once the sample reaches the target temperature.

MODE-2:
Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.

MODE-3:
The thermo-module can be turn off. Without temperature control, the measurement value is displayed in 4 seconds after the START key is pressed.

MODE-S:
Displays the measurement value once a certain level of sample stability is achieved.
Output terminals • Printer (for ATAGO digital printers)
• Computer -USB
Warranty 2 years standard (3 years with product registration) excluding touchscreen
Optional Software Refractosoft : Cat.No.3176
Digital Printer DP-63 : Cat.No.3118
Digital Printer DP-AD : Cat.No.3123
MAGIC™(metal) : RE-56180
MAGIC™ (resin) : RE-56185
Flow cell attachment : RE-56173
10% Sucrose (±0.01%) : RE-111001
20% Sucrose (±0.01%) : RE-112001
30% Sucrose (±0.01%) : RE-113001
40% Sucrose (±0.02%) : RE-114002
50% Sucrose (±0.02%) : RE-115002
* Calibration Certificate : Contact an ATAGO representative for details.
Parts Printer paper (regular) for DP-63 : RE-8412
Printer paper (long-term storage)for DP-63 : RE-8414
Printer paper for DP-AD : RE-89403
Ribbon cassette for DP-AD : RE-89402
• Fan Filter Replacement : RE-58001
[*1] When measuring a standard sucrose solution of up to 50% Brix or standard refractive index solution in MODE-1 at 20°C
¤U¸ü«¬¿ý ( English only )
Go to the product search GO TOP

¦Û°Ê§é®g»ö RX-5000α( alpha )-Plus

¥x¦¡§é®g»öRX-5000α(alpha)-Plus¬O¥HRX-5000α(alpha)§@¬°¼Ð­ã¨Ã´£°ª¨äºë«×ªº·s²£«~¡C¥¦ªººë«×¬°Brix ±0.010 ¦Ü nD ±0.00002.
¦¹²£«~¥i¥H¥H ¤º ¸mªºùÚ·Å¥\¯à§Ö³t¥B°ªºë«×¦a ´ú¶q¦UºØ²GÅ骺§é®g²v¡A Brix ¥H¤Î¿@«×:
• ¨ã¦³¤º¸mªºùÚ·Å¥\¯à¡A¤£»Ý­nùڷŤô½c¡C
• µ¥¹F¨ì¥Ø¼Ð·Å«×«á¦Û°Ê¶}©l´ú¶q¡C
• «Ü§Ö³t¦aÅã¥Ü§é®g²v¥H¤ÎBrix­È¡C
• ¨ã¦³Brix ±0.010 ¦Ü nD ±0.00002ªº°ªºë«×¡C
• ·|Åã¥Ü´ú¶qµ²ªG¬O§_¦b±z©Ò³]¸mªº½d³ò¤º¡C
• ±a¤â°Ê®Õ¥¿¥\¯à¡C
• ¯à°÷¿é¤J60ºØ¥Î¤á¼Ð«×¡C
• ¯à°÷«O¦s³Ì·sªº30­Ó´ú¶q¬ö¿ý¡C


ÂX¤j
¼Æ¶q

>Icon»¡©ú RS-232C Interface External temperature samples User scales can be inputted Measurement at a set temperature Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-5000α( alpha )-Plus «¬¸¹ 3266
´ú¶q½d³ò ©}§é«ü¼Æ (nD)
1.32700 ¦Ü 1.58000
¿}«×(Brix)
0.000 ¦Ü 100.000 %
( 5 ¦Ü 60¢XC ATC)
³Ì¤p«ü¥Ü­È ©}§é«ü¼Æ (nD) 0.00001
¿}«×(Brix) 0.005%
·Å«×: 0.01 C
´ú¶q·Ç½T«× ©}§é«ü¼Æ (nD)
± 0.00002
¿}«×(Brix) ± 0.010%
­«½Æ©Ê ©}§é«ü¼Æ (nD)
± 0.00001
¿}«×(Brix) ± 0.010%
´ú¶q·Å«× 5 ¦Ü 60°C ¹q·½ AC 100 ¦Ü 240V, 50/60Hz
¹q¤O·l¯Ó 65VA ¤Ø¤o­«¶q 37×26×14¤½¤À, 6.4¤d§J
(¤£§t¹s¥óªº­«¶q)
´ú¶q§Î¦¡ MODE-1:
Displays the measurement value once the sample reaches the target temperature.

MODE-2:
Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.

MODE-3:
The thermo-module can be turn off. Without temperature control, the measurement value is displayed in 4 seconds after the START key is pressed.

MODE-S:
Displays the measurement value once a certain level of sample stability is achieved.
¿é¥X²×ºÝ¾÷ •¦LªúÚ÷¿é¥X (ATAGO ¼Æ¦ì¦Lªí¾÷)
•RS-232C
¿ï¥ó Software Refractosoft : Cat.No.3176
• ¼Æ¦ì¦Lªí¾÷ DP-RX:«¬¸¹ 3121
• ¼Æ¦ì¦Lªí¾÷ DP-RD:«¬¸¹ 3122
MAGIC™(metal) : RE-56180
MAGIC™ (resin) : RE-56185
RX-5000α¥Î¸Ë¼Ëº|°« : RE-56172
10% ½©¿}·»²G (±0.01%): RE-111001
20% ½©¿}·»²G (±0.01%): RE-112001
30% ½©¿}·»²G (±0.01%): RE-113001
40% ½©¿}·»²G (±0.02%): RE-114002
50% ½©¿}·»²G (±0.02%): RE-115002
®ø¯Ó«~/¹s¥ó • RX-5000α¥Î¾÷¸n:RE-6532
DP-62α, DP-RX¥Î¥´¦L¯È:RE-8412
DP-62α, DP-RX¥Îªø®Ä¨Ï¥Î¥´¦L¯È:RE-8414
DP-RD¥Î¥´¦L¯È:RE-89403
DP-RD¥Î¾¥²°:RE-89402
• ³Æ¥Î (¥æ´«¥Î) ±Æ®ð¹LÂo¾¹:RE-58001
  ¤U¸ü«¬¿ý ( English only )
·j¯Á²£«~ GO TOP

¦Û°Ê§é®g»ö RX-5000α( alpha )

RX-5000α(alpha)¬O¯à°÷¤º³¡³]©w´ú¶q·Å«×ªº¦Û°Ê§é®g»ö¡A¯à°÷§Ö³t¦a´ú¶q©}§é«ü¼Æ¡B¿}«×©Î¦U¦¡²GÅ骺¿@«×¡A¥H¤U¬°¥»²£«~ªº¯S©Ê¡G
• ¦]¬°RX-5000α(alpha)¨ã¦³¹q¼ö¼Ò²Õ¥H±±¨ûÓūסA©Ò¥H¤£»Ý­n«úÓŤô½c¡C
• ¦b¼Ë¥»¹F¨ì¥Ø¼Ð·Å«×¤§«á¡A´ú¶q·|¦Û°Ê¶}©l¡C
• ¦b¥Ø¼Ð·Å«×¤U¡A©}§é«ü¼Æ»P¿}«×·|§Ö³tÅã¥Ü¡C
• ¥i¨ú±o°ª¿}«×(Brix) ± 0.03%»P©}§é«ü¼Æ ± 0.00004 ·Ç½T«×¡C
• RX-5000α(alpha)·|Åã¥Ü±z©Ò³]ªº±±¨ûÙd³òªº°ª§C¬É½u¡C
• ¦pªG´ú¶q­È»P±zªº¼Ð·Ç²GÅé­È©Î¨ä¥L§é®g»ö´ú¶qªº¤£¦P¡A±N¯à°µ³¡¤À½Õ¾ã¡C
• ®Ú¾Ú±zªº¼Ë¥»¡A¯à°÷¿é¤J60ºØ¨Ï¥ÎªÌ¼Ð«×¡C
• RX-5000α(alpha) ¯à°÷Åã¥Ü³Ì¤Ö30­Ó³Ìªñªº´ú¶q­È¡C

* RX-5000α(alpha) ¯S®í¼Ð«×
¦pªG»Ý­n¡A§Ú­Ì¥i¦bµo³f«e³]©w§é®g²v¤ÎBRIX(¥Õ§Q«×)¥H¥~ªº¥t¤@ºØ¼Ð«×(¨Ò¦p¸Á»e¤ô¤À¡AÆQ¤ô¿@«×µ¥)¡C ¦pªG¦³¤°»òºÃ°Ý¡A½ÐºÉºÞ»P§Ú­ÌÁp¨t¡C


ÂX¤j
¼Æ¶q

>Icon»¡©ú RS-232C Interface External temperature samples User scales can be inputted Measurement at a set temperature Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-5000α ( alpha ) «¬¸¹ 3261
´ú¶q½d³ò ©}§é«ü¼Æ (nD)
1.32700 ¦Ü 1.58000
¿}«×(Brix)
0.00 ¦Ü 100.00 %
( 5 ¦Ü 60¢XC ATC)
³Ì¤p«ü¥Ü­È ©}§é«ü¼Æ (nD) 0.00001
¿}«×(Brix) 0.01%
·Å«×: 0.01 C
´ú¶q·Ç½T«× ©}§é«ü¼Æ (nD)
± 0.00004
¿}«×(Brix) ± 0.03%
­«½Æ©Ê ©}§é«ü¼Æ (nD)
± 0.00002
¿}«×(Brix) ± 0.01%
´ú¶q·Å«× 5 ¦Ü 60°C ¹q·½ AC 100 ¦Ü 240V, 50/60Hz
¹q¤O·l¯Ó 65VA ¤Ø¤o­«¶q 37×26×14¤½¤À, 6.4¤d§J
(¤£§t¹s¥óªº­«¶q)
´ú¶q§Î¦¡ MODE-1:
Displays the measurement value once the sample reaches the target temperature.

MODE-2:
Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.

MODE-3:
The thermo-module can be turn off. Without temperature control, the measurement value is displayed in 4 seconds after the START key is pressed.

MODE-S:
Displays the measurement value once a certain level of sample stability is achieved.
¿é¥X²×ºÝ¾÷ •¦LªúÚ÷¿é¥X (ATAGO ¼Æ¦ì¦Lªí¾÷)
•RS-232C
¿ï¥ó Software Refractosoft : Cat.No.3176
• ¼Æ¦ì¦Lªí¾÷ DP-RX:«¬¸¹ 3121
• ¼Æ¦ì¦Lªí¾÷ DP-RD:«¬¸¹ 3122
MAGIC™(metal) : RE-56180
MAGIC™ (resin) : RE-56185
RX-5000α¥Î¸Ë¼Ëº|°« : RE-56172
10% ½©¿}·»²G (±0.01%): RE-111001
20% ½©¿}·»²G (±0.01%): RE-112001
30% ½©¿}·»²G (±0.01%): RE-113001
40% ½©¿}·»²G (±0.02%): RE-114002
50% ½©¿}·»²G (±0.02%): RE-115002
®ø¯Ó«~/¹s¥ó • RX-5000α¥Î¾÷¸n:RE-6532
DP-62α, DP-RX¥Î¥´¦L¯È:RE-8412
DP-62α, DP-RX¥Îªø®Ä¨Ï¥Î¥´¦L¯È:RE-8414
DP-RD¥Î¥´¦L¯È:RE-89403
DP-RD¥Î¾¥²°:RE-89402
• ³Æ¥Î¡]¥æ´«¥Î¡^±Æ®ð¹LÂo¾¹:RE-58001
¤U¸ü«¬¿ý ( English only )
·j¯Á²£«~ GO TOP

¦Û°Ê§é®g»ö RX-5000α-Bev

RX-5000α-Bev¬O¬°¤F¶¼®Æ¼t®a¨î³yªºRX¨t¦C²£«~.¥Ñ¤_¦¹²£«~ªºµÙÃ襭, ¼Ë«~«Ü®e©öÀ¿±¼ RX-5000α-Bev¨ã¦³RX-5000α©Ò¨ã¦³ªº¦U¶µ¥\¯à

ÂX¤j
¼Æ¶q

>Icon»¡©ú RS-232C Interface External temperature samples User scales can be inputted Measurement at a set temperature Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-5000α-Bev «¬¸¹ 3271
´ú¶q½d³ò ©}§é«ü¼Æ (nD):
1.32700 ¦Ü 1.58000
¿}«×(Brix):
0.00 ¦Ü 100.00%
( 5 ¦Ü 60°C ATC)
³Ì¤p«ü¥Ü­È ©}§é«ü¼Æ (nD):0.00001
¿}«×(Brix) :0.01%
·Å«× :0.01°C
´ú¶q·Ç½T«× ©}§é«ü¼Æ (nD):±0.00004
¿}«×(Brix) :±0.03%
­«½Æ©Ê ©}§é«ü¼Æ (nD):±0.00002
¿}«×(Brix):±0.01%
´ú¶q·Å«× 5 ¦Ü 60°C ¹q·½ AC100V ¦Ü 240V, 50/60Hz
¹q¤O·l¯Ó 65VA ¤Ø¤o­«¶q 37×26×14¤½¤À, 6.4¤d§J (¤£§t¹s¥óªº­«¶q)
´ú¶q§Î¦¡ MODE-1:
Displays the measurement value once the sample reaches the target temperature.

MODE-2:
Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.

MODE-3:
The thermo-module can be turn off. Without temperature control, the measurement value is displayed in 4 seconds after the START key is pressed.

MODE-S:
Displays the measurement value once a certain level of sample stability is achieved.
¿é¥X²×ºÝ¾÷ • ¦LªúÚ÷¿é¥X ( ¼Æ¦ì¦Lªí¾÷ ATAGO )
• RS-232C
¿ï¥ó Software Refractosoft : Cat.No.3176
• ¼Æ¦ì¦Lªí¾÷ DP-RX:«¬¸¹ 3121
• ¼Æ¦ì¦Lªí¾÷ DP-RD:«¬¸¹ 3122 Z
10% ½©¿}·»²G (±0.01%): RE-111001
20% ½©¿}·»²G (±0.01%): RE-112001
30% ½©¿}·»²G (±0.01%): RE-113001
40% ½©¿}·»²G (±0.02%): RE-114002
50% ½©¿}·»²G (±0.02%): RE-115002
®ø¯Ó«~/¹s¥ó • RX-5000α-Bev¥Î¾÷¸n:RE-65159
DP-RX¥Î¥´¦L¯È:RE-8412
DP-RX¥Îªø®Ä¨Ï¥Î¥´¦L¯È:RE-8414
DP-RD¥Î¥´¦L¯È:RE-89403
DP-RD¥Î¾¥²°:RE-89402
• ³Æ¥Î¡]¥æ´«¥Î¡^±Æ®ð¹LÂo¾¹:RE-58001
¤U¸ü«¬¿ý ( English only )
·j¯Á²£«~ GO TOP

¦Û°Ê§é®g»ö RX-7000α( alpha )

RX-7000¬O¨ÌRX-5000α(alpha)©}§é«ü¼Æªº´ú¶q½d³ò»P´ú¶q·Å«×¦A¥[¥H§ïµ½ªº¤É¯Åª©¥»¡A¨Ã¨ã¦³¼ö¹q¼Ò²Õ¥Hºû«ù«í·Å¡C³Ì¾A¦X¥Î¨Ó¿Å¶qªo«~»P¯×ªÕªº°ª¿ÄÂI¡B¸û°ª©}§é«ü¼Æªº­»¤ô¡B¦³¾÷·»¾¯µ¥¡C¥»²£«~¨ã¦³¤â°Ê¨è«×¨î­q¥\¯à¡A¥i¥H¨ó½Õ¨ä¥L§é®g»ö©Ò´ú¶qªº¤£¦P¼Ð·Ç²GÅé­È»P´ú¶q­È¡C


ÂX¤j
¼Æ¶q

>Icon»¡©ú RS-232C Interface User scales can be inputted Measurement at a set temperature External temperature samples High temperature samples Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-7000α( alpha ) «¬¸¹ 3262
´ú¶q½d³ò ©}§é«ü¼Æ (nD) :
1.3250 ¦Ü 1.7000
¿}«×(Brix) :
0.0 ¦Ü100.0%
(ATC:5 ¦Ü 70°C)
³Ì¤p«ü¥Ü­È ©}§é«ü¼Æ (nD):
0.0001/0.00001 (¥i¿ï¾Ü)
¿}«× (Brix) :
0.1% / 0.01% (¥i¿ï¾Ü)
·Å«×: 0.01
´ú¶q·Ç½T«× ©}§é«ü¼Æ (nD)
± 0.0001
¿}«× (Brix) ± 0.1%
´ú¶q·Å«× 5 ¦Ü 70°C
­«½Æ©Ê ©}§é«ü¼Æ (nD) ± 0.00005
¿}«× (Brix) ± 0.2%
¹q·½ AC 100 ¦Ü 240V, 50/60Hz
¹q¤O·l¯Ó 65VA ¤Ø¤o­«¶q 37×26×14¤½¤À, 6.8¤d§J
(¤£§t¹s¥óªº­«¶q)
´ú¶q§Î¦¡ MODE-1:
Displays the measurement value once the sample reaches the target temperature.

MODE-2:
Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.

MODE-3:
The thermo-module can be turn off. Without temperature control, the measurement value is displayed in 4 seconds after the START key is pressed.

MODE-S:
Displays the measurement value once a certain level of sample stability is achieved.
¿é¤J²×ºÝ¾÷ •¦LªúÚ÷¿é¥X ( ¼Æ¦ì¦Lªí¾÷ ATAGO )
•RS-232C
¿ï¥ó Software Refractosoft : Cat.No.3176
• ¼Æ¦ì¦Lªí¾÷ DP-RX:«¬¸¹ 3121
• ¼Æ¦ì¦Lªí¾÷ DP-RD:«¬¸¹ 3122
MAGIC™(metal) : RE-56180
MAGIC™ (resin) : RE-56185
RX-7000α¥Î¸Ë¼Ëº|°« : RE-56173
10% ½©¿}·»²G (±0.01%): RE-111001
20% ½©¿}·»²G (±0.01%): RE-112001
30% ½©¿}·»²G (±0.01%): RE-113001
40% ½©¿}·»²G (±0.02%): RE-114002
50% ½©¿}·»²G (±0.02%): RE-115002
®ø¯Ó«~/¹s¥ó • RX-7000α¥Î¾÷¸n:RE-6532
DP-62α, DP-RX¥Î¥´¦L¯È:RE-8412
DP-62α, DP-RX¥Îªø®Ä¨Ï¥Î¥´¦L¯È:RE-8414
DP-RD¥Î¥´¦L¯È:RE-89403
DP-RD¥Î¾¥²°:RE-89402
• ³Æ¥Î¡]¥æ´«¥Î¡^±Æ®ð¹LÂo¾¹:RE-58001
¤U¸ü«¬¿ý ( English only )
·j¯Á²£«~ GO TOP

¦Û°Ê§é®g»ö RX-9000α ( alpha )

RX-9000α¬OATAGO¼Æ¦r¦¡§é®g»ö¤¤³Ì°ª©Ê¯à²£«~¡C ¦¹²£«~¨ã¦³¼sªxªº´ú¶q½d³ò,´ú¶q·Å«×¤Î«Ü°ªªº´ú¶qºë«×,¥i¼sªx¾A¥Î¤_º²ÂI°ªªºªo¯×¤Î§é®g²vªº°ªªº­»®Æ,¦³¾÷·»¾¯ªº´ú¶qµ¥¡C¥¦¸Ë³ÆùÚ·Å¥\¯à, ¥»²£«~¨ã¦³¤â°Ê®Õ¥¿¥\¯à¡A¥i¸É¥¿¼Ð­ã­È,»P¼Ð­ã²G©Î¨ä¥L§é®g»öªºÅª­È¦P¨B¤Æ

ÂX¤j
¼Æ¶q

>Icon»¡©ú RS-232C Interface User scales can be inputted Measurement at a set temperature External temperature samples High temperature samples Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-9000α «¬¸¹ 3263
´ú¶q½d³ò ©}§é«ü¼Æ(nD)
1.32500 ¦Ü 1.70000
¿}«×(Brix)
0.00 ¦Ü 100.00 %
(ATC:5 ¦Ü 70°C)
³Ì¤p«ü¥Ü­È ©}§é«ü¼Æ(nD)
0.00001/0.0001 (¥i¿ï¾Ü)
¿}«×(Brix)
0.01% / 0.1% (¥i¿ï¾Ü)
·Å«×: 0.01°C
´ú¶q·Ç½T«× • ©}§é«ü¼Æ(nD):±0.00004
(nD 1.33299 ¦Ü 1.42009,´ú¶q·Å«× 10.00 ¦Ü 30.00°C )
• ©}§é«ü¼Æ(nD):±0.00010 (¤W­±½d³ò¥H¥~)
• ¿}«×(Brix):±0.03%
(Brix 0.00 ¦Ü 50.00%,´ú¶q·Å«× 10.00 ¦Ü 30.00°C)
• ¿}«×(Brix):±0.05%
(Brix 50.01 ¦Ü 95.00%,´ú¶q·Å«×10.00 ¦Ü 30.00°C)
• ¿}«×(Brix):±0.10%
(°£¤F¤W­±¥H¥~³£¬OBRIX±0.10%¥HMODE1´ú¶q½©¿}²G®É)
­«½Æ©Ê • ©}§é«ü¼Æ (nD):±0.00002
(nD 1.33299 ¦Ü 1.42009 ´ú¶q·Å«× 10.00 ¦Ü 30.00°C )
• ©}§é«ü¼Æ (nD):±0.00005 (¤W­±½d³ò¥H¥~)
• ¿}«×(Brix):±0.01%
(Brix 0.00 ¦Ü 50.00%,´ú¶q·Å«× 10.00 ¦Ü 30.00°C )
• ¿}«×(Brix):±0.02%
(°£¤F¤W­±¥H¥~³£¬OBRIX±0.02%¥HMODE1´ú¶q½©¿}²G®É)
´ú¶q·Å«× 5 ¦Ü 70°C ¤Ø¤o­«¶q 37×26×14¤½¤À, 6.8¤d§J
(¤£§t¹s¥óªº­«¶q)
¹q¤O·l¯Ó 65VA ¹q·½ AC100V ¦Ü 240V, 50/60Hz
´ú¶q§Î¦¡ MODE-1:
Displays the measurement value once the sample reaches the target temperature.

MODE-2:
Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.

MODE-3:
The thermo-module can be turn off. Without temperature control, the measurement value is displayed in 4 seconds after the START key is pressed.

MODE-S:
Displays the measurement value once a certain level of sample stability is achieved.
¿é¥X²×ºÝ¾÷ •¦LªúÚ÷¿é¥X ( ATAGO ¼Æ¦ì¦Lªí¾÷ )
•RS-232C
¿ï¥ó Software Refractosoft : Cat.No.3176
• ¼Æ¦ì¦Lªí¾÷ DP-RX:«¬¸¹ 3121
• ¼Æ¦ì¦Lªí¾÷ DP-RD:«¬¸¹ 3122
MAGIC™(metal) : RE-56180
MAGIC™ (resin) : RE-56185
RX-9000α¥Î¸Ë¼Ëº|°« : RE-56173
10% ½©¿}·»²G (±0.01%): RE-111001
20% ½©¿}·»²G (±0.01%): RE-112001
30% ½©¿}·»²G (±0.01%): RE-113001
40% ½©¿}·»²G (±0.02%): RE-114002
50% ½©¿}·»²G (±0.02%): RE-115002
®ø¯Ó«~/¹s¥ó • RX-9000α¥Î¾÷¸n:RE-6532
DP-RX¥Î¥´¦L¯È:RE-8412
DP-RX¥Îªø®Ä¨Ï¥Î¥´¦L¯È:RE-8414
DP-RD¥Î¥´¦L¯È:RE-89403
DP-RD¥Î¾¥²°:RE-89402
• ³Æ¥Î¡]¥æ´«¥Î¡^±Æ®ð¹LÂo¾¹:RE-58001
¤U¸ü«¬¿ý ( English only )
·j¯Á²£«~ GO TOP

¯ù.§C¿}¶¼®Æ¿@«×­p RX-007α (alpha)

RX-007£\¥i¥H¹F¨ìºë«×±0.005%, ¾A¥Î¤_´ú¶q¿@«×¥¼¨ì5%ªººñ¯ù,¬õ¯ù,¯QÀs¯ù¤Î¨ä¥L§C¿}¶¼®Æ. ¾Þ§@¤èªk²³æ, ¥u­n±N¼Ë¥»ºw¦bµÙÃè¤W­±«ö¶}©lÁä´N¥i¥H¤F.»P¨ä¥LRX¨t¦C¤@¼Ë¨ã¦³ùÚ·Å¥\¯à.


ÂX¤j
¼Æ¶q

>Icon»¡©ú RS-232C Interface External temperature samples User scales can be inputted Measurement at a set temperature Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-007α «¬¸¹ 3921
´ú¶q½d³ò Brix 0.000 ¦Ü 5.000%
©}§é«ü¼Æ(RI)
1.330150 ¦Ü 1.341500
³Ì¤p«ü¥Ü­È Brix 0.001%
©}§é«ü¼Æ (RI) 0.000001
·Å«× 0.01°C
´ú¶q·Ç½T«× Brix±0.005%
©}§é«ü(RI):±0.000010
(¦b20«×Äá¤ó)
(¦b¬Y­ÓÀô¹Ò·Å«×»PùڷŷūפU)
¤Ø¤o­«¶q 37×26×14¤½¤À, 6.7¤d§J
(¤£§t¹s¥óªº­«¶q)
´ú¶q·Å«× 15.00 ¦Ü 30.00°C ´ú¶q§Î¦¡ 2 ºØ§Î¦¡
¹q·½ AC100V ¦Ü 240V, 50/60Hz
¹q¤O·l¯Ó 65VA
¦LªúÚ÷¿é¥X • ¦LªúÚ÷¿é¥X (¼Æ¦ì¦Lªí¾÷ ATAGO )
• RS-232C
¿ï¥ó Software Refractosoft : Cat.No.3176
• ¼Æ¦ì¦Lªí¾÷ DP-RX:«¬¸¹ 3121
• ¼Æ¦ì¦Lªí¾÷ DP-RD:«¬¸¹ 3122
®ø¯Ó«~/¹s¥ó • RX-007α¥Î¾÷¸n:RE-56157
DP-RX¥Î¥´¦L¯È:RE-8412
DP-RX¥Îªø®Ä¨Ï¥Î¥´¦L¯È:RE-8414
DP-RD¥Î¥´¦L¯È:RE-89403
DP-RD¥Î¾¥²°:RE-89402
• ³Æ¥Î¡]¥æ´«¥Î¡^±Æ®ð¹LÂo¾¹:RE-58001
¤U¸ü«¬¿ý ( English only )
·j¯Á²£«~ GO TOP

¦Û°Ê§é®g»ö RX-5000

¦¹²£«~»PRX-alpha¨t¦C¤£¦P¡A¤£±aùÚ·Å¥\¯à¡A¥¦¥i¥H»PùڷŤô½c³s±µ±±¨î·Å«×´ú¶q¡C¨ä¥L¯S©º§¹¥þ»PRX-alpha¨t¦C¦P¼Ë¡C


ÂX¤j
¼Æ¶q
>Icon»¡©ú RS-232C Interface User scales can be inputted Measurement at a set temperature External temperature samples Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-5000 «¬¸¹ 3281
´ú¶q½d³ò ©}§é«ü¼Æ(nD)
1.32700 ¦Ü 1.58000
¿}«×(Brix)
0.00 ¦Ü 100.00%
³Ì¤p«ü¥Ü­È ©}§é«ü¼Æ(nD) 0.00001
¿}«×(Brix) 0.01%
´ú¶q·Ç½T«× ©}§é«ü¼Æ(nD)
± 0.00004
¿}«×(Brix) ± 0.03%
­«½Æ©Ê ©}§é«ü¼Æ(nD)
± 0.00002
¿}«×(Brix) ± 0.01%
·Å«×®Õ¥¿ 5 ¦Ü 60°C ´ú¶q·Å«× 5 ¦Ü 40°C
¹q¤O·l¯Ó 30VA ¹q·½ AC100 ¦Ü 240V, 50/60Hz
¤Ø¤o­«¶q 37×26×14¤½¤À, 6.4¤d§J
(¤£§t¹s¥óªº­«¶q)
¿é¤J¹qÀ£
¿é¥X¹qÀ£
§é®g»ö DC5V, 6A
¦Lªí¾÷ DC6.5V, 1.5
¿é¥X²×ºÝ¾÷ ¦Lªí¾÷¿é¥X ( ¼Æ¦ì¦Lªí¾÷ DP-RX )
RS-232C ¿é¥X
¿ï¥ó Software Refractosoft : Cat.No.3176
• ¼Æ¦ì¦Lªí¾÷ DP-RX:«¬¸¹ 3121
• ¼Æ¦ì¦Lªí¾÷ DP-RD:«¬¸¹ 3122
10% ½©¿}·»²G (±0.01%): RE-111001
20% ½©¿}·»²G (±0.01%): RE-112001
30% ½©¿}·»²G (±0.01%): RE-113001
40% ½©¿}·»²G (±0.02%): RE-114002
50% ½©¿}·»²G (±0.02%): RE-115002
®ø¯Ó«~/¹s¥ó • RX-5000¥Î¾÷¸n:RE-6532
• ²Ï±a:RE-8507
DP-62α, DP-RX¥Î¥´¦L¯È:RE-8412
DP-62α, DP-RX¥Îªø®Ä¨Ï¥Î¥´¦L¯È:RE-8414
DP-RD¥Î¥´¦L¯È:RE-89403
DP-RD¥Î¾¥²°:RE-89402
·j¯Á²£«~ GO TOP

¼Æ¦ì¦Lªí¾÷ DP-62( AD )

DP-62 ¬O¦Û°Ê§é®g»öRX¨t¦Cªº±M¥Î¦LªúÚ÷¡C·úÅ}§é«×­p´ú¶q§¹¦¨®É¡B¥¦¯à¦Û°Ê¦C¦L¥X¼Ë¥»½s¸¹¡B©}§é«ü¼Æªº´ú¶q­È (nD ©Î nDt)¡B¿}«×(Brix)(%)¡B¿@«×(%)(¨Ï¥ÎªÌ¼Ð«×)¡B»P´ú¶q·Å«×¡C


ÂX¤j
¼Æ¶q
Model DP-62(AD) «¬¸¹ 3148
¦C¦L¤è¦¡ ¼ö±Ó¥´¦L ¹q·½ DC8.5V ±q§é®g»ö
¹q¤O·l¯Ó 13VA ¤Ø¤o­«¶q 17×16×7¤½¤À, 580¤½§J
(¤£§t¹s¥óªº­«¶q)
®ø¯Ó«~/¹s¥ó DP-62¥Î¥´¦L¯È:RE-8412
DP-62¥Îªø®Ä¨Ï¥Î¥´¦L¯È:RE-8414
·j¯Á²£«~ GO TOP

¼Æ¦ì¦Lªí¾÷ DP-RX

¦Û°Ê§é®g»ö RX-5000α(§Ç¸¹³o¾A¥Î¤_¼Æ¦r¦¡§é®g»öRX-5000α(§Ç¸¹No.052601¥H¤W)¤ÎRX-7000α(§Ç¸¹No.051301¥H¤W).¥i¦Û°Ê¥´¦L§é®g²v(nD) Brix%¡B¥Î¤á¼Ð«×¡B´ú¶q·Å«×.


ÂX¤j
¼Æ¶q
Model DP-RX «¬¸¹ 3121
¦C¦L¤è¦¡ ¼ö±Ó¥´¦L ¹q·½ AC100 ¦Ü 240V
¹q¤O·l¯Ó 13VA ¤Ø¤o­«¶q 17×16×7¤½¤À, 580¤½§J
(¤£§t¹s¥óªº­«¶q)
®ø¯Ó«~/¹s¥ó DP-RX¥Î¥´¦L¯È:RE-8412
DP-RX¥Îªø®Ä¨Ï¥Î¥´¦L¯È:RE-8414
·j¯Á²£«~ GO TOP

¼Æ¦ì¦Lªí¾÷ DP-RD

DP-RD ¬ORX-ALPHA¨t¦C¨Ï¥Îªº¥´¦L¾÷. DP-RD¥i¦Û°Ê¥´¦L¼Ë«~¸¹¡B§é®g²v¡BBRIX­È¡B¿@«×(%)(¥Î¤á¼Ð«×¤@ºØ)¤Î´ú¶q·Å«×¡B¹ïÀ³´¶³q¥´¦L¯È.


ÂX¤j
¼Æ¶q
Model DP-RD «¬¸¹ 3122
¦C¦L¤è¦¡ À»¥´¦¡ÂI°}¥´¦L¾÷
(°w¦¡¥´¦L¾÷)
¹q·½ AC100 ¦Ü 240V, 50/60Hz
¹q¤O·l¯Ó 7VA ¤Ø¤o­«¶q 11×18×9¤½¤À, 470¤½§J
(¤£§t¹s¥óªº­«¶q)
®ø¯Ó«~/¹s¥ó DP-RD¥Î¥´¦L¯È:RE-89403
DP-RD¥Î¾¥²°:RE-89402
·j¯Á²£«~ GO TOP