Liberation from All Previous Hussle New Type of Digital Viscometer
-In compliance with ISO1652, ISO2555-

VISCO™ B
VISCO™ B

Digital Viscometer

VISCO™ B

SDGs

6 Points that Surpasses the Existing Digital Viscometer

Easy Operation

Easy Operation

ATAGO’s VISCO ™ B offers a simple set up and all operations can be done by one dial button for measurements which allows anyone to easily assemble and use.

One Touch Spindle

One Touch Spindle

Compared to the left-handed screw type that are commonly used with traditional Type-B viscometers, a spindle for VISCO™ B can be installed by simple one touch.

Smooth Height Adjustment

Smooth Height Adjustment

Many of the traditional Type-B viscometers that use left-hand screw requires to turn and twist screws to move it up and down causing tendonitis in some cases. With VISCO™ B, height can be adjusted simply by using a lever.

Digital Level Check

Digital Level Check

Traditional Type-B analog viscometers require visual check when leveling. VISCO™ B is digital and easily done.

Don’t let reference lines confuse you

Don’t let reference lines confuse you

Where to place a beaker is important. VISCO™ B has easy to follow guideline that takes away the ambiguity.

Stylish design

Stylish design

The VISCO™ B offers futuristic design that will brighten and bring fun to any measurement sites.

Setup Video GuideSetup Video Guide

【 VISCO™ B 】Line Up

Model

Package

New!
PackageE

Includes Temp controller

PackageE

Options

New!
All in one

Compatible for VISCO/VISCO895/
VISCO B(L)

All set


Temp Controller


VISCO B(L)

For all range including low-viscosity


Water jacket

Connect with
circulating water bath

Water jacket


60-C5

Circulating
water bath

60-C5


Function and Design

Calibration compares the true value and the value measured from the instrument. Calibration is an important task to ensure the reliability of the measurement results. Calibration is recommended when the measurement environment has changed drastically or when the measurement results are out of the norm. If you are considering routine calibration, we recommend that you decide the frequency based on the circumstance in which the instrument is used and past measurement results. ATAGO's viscometer VISCO™ provides the following standard solutions: The standard solutions are available in various viscosity. It is recommended to calibrate with a standard solution that is close to the viscosity of samples being measured.

●VISCO™ standard solution●

Part number Part name Contents
RE-89053 Viscosity Standard LiquidJS20 500mL
RE-89054 Viscosity Standard LiquidJS50 500mL
RE-89055 Viscosity Standard LiquidJS100 500mL
RE-89056 Viscosity Standard LiquidJS200 500mL
RE-89057 Viscosity Standard LiquidJS500 500mL
RE-89058 Viscosity Standard LiquidJS1000 500mL
RE-89059 Viscosity Standard LiquidJS2000 500mL

Feel free to order or consult from this form Please contact me

VISCO™ B Water jacket

This is water jacket for VISCO™ B which could be connected to water bath
60-C5.
Specifications
Model Water jacket
Cat.No. 6845
Dimensions & Weight Width 147 x depth 150 x height 144
Weight: 1.9kg
Beaker size Diameter :75㎜Φ~90㎜Φ
Height: Approx.120㎜
Usable temperature 5℃ to 70℃
Water jacket

VISCO™ B Water jacket

Close

Circulating Constant Temperature Bath 60-C5

60-C5 $4,500.00 USD
The 60-C5 is an external circulation type constant temperature water tank provided with a thermo-module. The temperature can be set in the range of 10 to 60°C and the unit is perfectly suited for connection with a refractometer.An upgraded version of the 60-C4 model, featuring an increased tank capacity of 1.0L and an improved resolution of 0.1℃ which makes it even easier to use.
Specifications
Model 60-C5
Cat.No. 1923
Tank Capacity 1.0 lit
Resolution 0.1℃
Temperature Setting Range 10 to 60°C (water)
Temp.control PID control method using a thermo-module
Dimensions & Weight 20.4×33.6×28.9cm, 9.0kg
Flow Rate 6 lit / min
60-C5

Circulating Constant Temperature Bath 60-C5

Close

What is a Viscometer?

Type and Measurement Principle of Viscometer There are different types viscometers that uses various measurement methods.
For example, in the Japanese Industrial Standard JIS Z 8803, viscometers are classified as follow:
• Capillary viscometers        • Falling ball viscometers
• Rotational viscometers     • Vibrational viscometers
There are also other measurement methods such as viscosity cups and Line Spread Tests (LST).
ATAGO's viscosity meter VISCO™ is measured on a principle called rotational viscosity.

Principle of Rotational Viscometer

Principle of Rotational Viscometer Rotational viscometer is one of the most common viscometers used. The structure is simple, easy to use, and the measurement range is wide and can be measured with high accuracy. When a cylindrical spindle is placed in the sample and rotated at a constant speed, the viscosity is determined by measuring the torque (shear stress) acting on the cylindrical surface. There are different types of spindles: coaxial double cylinder, single cylindrical, and cone and plate. The cone plate type can determine the flow characteristics of non-Newtonian fluids by changing the rotational speed.

Purchase here Purchase here

Purchase