英語_言語選択アイコン
go to onlineshop

World's First Hybrid

Brix and Salt Hybrid Meter
PAL-BX|SALT

SDGs
相棒=PAL 徹底的に研究したものはまず人の手だった…、コンセプトページへはこちらから

6 Reasons for choosing our Brix and Salt Hybrid Meter

Optical prism and titanium dual electrode

Optical prism and titanium dual electrode

A hybrid brix and salt meter born by the fusion of optics and metal.An optical prism is used for the concentration via light refraction, and titatanium for salt concentration via electrical conductivity.

Pursuing SDGs, it can withstand long-term use.

Pursuing SDGs, it can withstand long-term use

The concept of `anyone`, `anywhere` and `easily` being able to measure has been our standard, but now we have added `for a long time` to our list for the strongest of specifications. Working towards sustainability, the PAL-BX/SALT is made of durable materials designed for long term use without worry.

World's first! Dilution-free Salt Measurement

World's first! Dilution-free Salt Measurement

Yes, I was looking for something like this!‘Not only providing the means to measure the balance between concentration and salt content in one unit, the decisive factor in taste for all food, with our proprietary algorithm we also took away the stress that comes with dilution.

No reagents or glassware required

No reagents or glassware required

Costly and hard to dispose of reagents were needed for the titration method. Glass hydrometers needed to be handled carefully in food facilities due to the danger of dropping and shattering glass. Now with the Brix and Salt Meter,, you don’t have to worry about reagents or damaged glass!

Anyone can measure easily

Anyone can measure easily

When using for the first time, a simple programming with 1 undiluted and 2 diluted versions of the sample is needed. After measuring the Brix and salt of the three samples, the user scale is automatically created from those values. From then on, that sample can be dropped on the unit and measured without any dilution!

It can be cleaned under running water.

It can be cleaned under running water

Since is water resistant (IP65), it can be rinsed under running water after measurement. Highly viscous samples can also be rinsed with water..
This meter can withstand the harsh conditions in the kitchen or on the production line.

Setup Video GuideSetup Video Guide

【PAL-BX|SALT】Applications

Applications

Lineup

Model

New!
PAL-BX|SALT+5

With 5 user scales,
No dilution required!

PAL-BX/SALT+5

New!
PAL-BX|SALT

Simple combination
of Brix & Salt

PAL-BX/SALT

Function & Design

PAL™-BX | SALT + 5 Measurement Method
To prepare for measurement, press the heart key for 5 seconds or more to select the scale.

step1
step2
step3

QCan both the PAL-BX | SALT and PAL-BX | SALT + 5 measure salt content without dilution?

AOnly the PAL-BX | SALT + 5 has the user scale function to measure salt content without dilution


QHow many user scales can be registered on the PAL-BX/SALT +5?

AUp to 5 user scales can be registered.


QWhat is the user scale on the PAL-BX | SALT + 5?

AIt is function that allows samples with high Brix, like soy sauce, to be measured without dilution.


QWhat is the heart key?

APress the heart key to display the salt reduction index (salt concentration ÷ Brix).


QIs it possible to measure high temperature samples?

AIt is equipped with a temperature compensation feature to accurately measure high-temperature samples.


QHow should I store the unit ?

AIf the unit will not be used for a while, please store it in the original case it came in.

Product details

Digital Hand-held “Pocket” Brix-Salt Meter PAL-BX|SALT+5

This is a hybrid of refractometer and salt meter which has an optical prism is used to measure the concentration (Brix) and titanium electrode is used to measure the salt contents.
It enables to check the balance between concentration(Brix) and salt that is the decisive factor for taste in foods in general.


In addition, we pursued the elimination of the dilution which is required for salt measurement especially for the concentrated samples like sauce.
Now, the salt concentration of samples with high concentration such as sauce can be measured without dilution.

Specifications
Model PAL-BX|SALT+5
Cat.No. 4922
Scale Brix
Salt concentration
Range Brix : 0.00 to 90.0%
Salt concentration : 0.00 to 15.00%
Resolution Brix : 0.1%
Salt concentration : 0.01%
Accuracy Brix : ±0.2%
Displayed value : ±0.05%
(for salt concentration of 0.00 to 0.99%)
Relative precision : ±5%
(for salt concentration of 1.00 to 9.99%)
Relative precision : ±10%
(for salt concentration of 10.00 to 15.00%)
Sample temp. 10 to 100℃
Power Supply 2 × AAA Batteries
International Protection Class IP65 Water resistant
Dimensions & Weight Main Unit : 55(W)×31(D)×109(H)mm, 100g

· NaCl Solution 2.50% (±0.05%) AB250 [*1] : RE-120250

PAL-BX|SALT+5

Digital Hand-held “Pocket” Brix-Salt Meter PAL-BX|SALT+5

Close

Digital Hand-held “Pocket” Brix-Salt Meter PAL-BX|SALT

This is a hybrid of refractometer and salt meter which has an optical prism is used to measure the concentration (Brix) and titanium electrode is used to measure the salt contents. Furthermore, it equipped with an offset function to show the same value as other measurement methods.

Specifications
Model PAL-BX|SALT
Cat.No. 4921
Scale Brix
Salt concentration
Range Brix : 0.00 to 90.0%
Salt concentration : 0.00 to 15.00%
Resolution Brix : 0.1%
Salt concentration : 0.01%
Accuracy Brix : ±0.2%
Displayed value : ±0.05%
(for salt concentration of 0.00 to 0.99%)
Relative precision : ±5%
(for salt concentration of 1.00 to 9.99%)
Relative precision : ±10%
(for salt concentration of 10.00 to 15.00%)
Sample temp. 10 to 100℃
Power Supply 2 × AAA Batteries
International Protection Class IP65 Water resistant
Dimensions & Weight Main Unit : 55(W)×31(D)×109(H)mm, 100g

· NaCl Solution 2.50% (±0.05%) AB250 [*1] : RE-120250

PAL-BX|SALT

Digital Hand-held “Pocket” Brix-Salt Meter PAL-BX|SALT

Close

Digital Hand-held "Pocket" SALT METER PAL-SALT

PAL-SALT is widely used in various industries for food and industrial solutions. For food products, in addition to checking salt content, salt meter is used to make sure salt is properly added and not forgotten for such product as bread, rice balls and frozen. For industrial use, salt meter is widely used for salt resistance test for cars and such.
*Offset feature use examples
#1. Program a dilution factor to display the original salt%
#2. Program a conversion factor to align the readings with titration methods.

Specifications
Model PAL-SALT
Cat.No. 4250
Scale Salt concentration (g/100g)
Temperature
Method Conductivity method
Range 0.00 to 10.0% (g/100g)
Resolution 0.01% for salt concentration of 0.00 to 2.99%
0.1% for salt concentration of 3.0 to 10.0%
Accuracy Displayed value ±0.05%
(for salt concentration of 0.00 to 0.99%)
Relative precision ±5%
(for salt concentration of 1.00 to 10.0%)
Sample temp. 5 to 100°C

· PAL-CASE : RE-39409

· STRAP : RE-39410

· NaCl Solution 2.50% (±0.05%) AB250 [*1] : RE-120250

· Battery Case Cover With O-Ring : RE-38163

· USB Battery Charger : RE-34801

[*1] Calibration Certificate : Contact an ATAGO representative for details.

PAL-SALT

Digital Hand-held "Pocket" SALT METER PAL-SALT

Close

Digital Hand-held "Pocket" SALT METER PAL-SALT Mohr

PAL-SALT Mohr gives a reading similar to those obtained from the Mohr’s method (titration). Like other ATAGO salt meters, PAL-SALT Mohr utilizes conductivity to measure samples. This unit also features an offset function which allows for readings to be compensated based on known standards.

Specifications
Model PAL-SALT Mohr
Cat.No. 4251
Scale Salt concentration (g/100mL)
Temperature
Method Conductivity method
Range 0.00 to 10.0% (g/100mL)
Resolution 0.01% for salt concentration of 0.00 to 2.99%
0.1% for salt concentration of 3.0 to 10.0%
Accuracy Displayed value ±0.05%
(for salt concentration of 0.00 to 0.99%)
Relative precision ±5%
(for salt concentration of 1.00 to 10.0%)
Sample temp. 5~100℃

· PAL-CASE : RE-39409

· STRAP : RE-39410

· JORDAN for PAL(Silicon Cover) : RE-39414

· NaCl Solution 2.50% (±0.05%) AB250 [*1] : RE-120250

· Battery Case Cover With O-Ring : RE-38163

· USB Battery Charger : RE-34801

PAL-SALT Mohr

Digital Hand-held "Pocket" SALT METER PAL-SALT Mohr

Close

Digital salt-meter ES-421

The digital salt-meter, ES-421 employs a funnel-shaped sensor which measures the salt % of a sample such as the dilute solution of soy sauce, ketchup,mayonnaise, worcester sauce, squeezed juice of pickles, etc. It only needs 1.0ml of sample.
*Improved durability with titanium electrodes.
*Stage is made out of SUS316L.
*Equipped with a backlight for even brighter, easier to read display.
*Equipped with an “Offset Function.”

*The NaCl solution for calibration is different from the solution used for the former ES-421(Cat.No4210).Its concentration has been changed from 2.84%→2.50%.

Specifications
Model ES-421
Cat.No. 4211
Scale Salt concentration (g/100g)
Temperature
Method Conductivity method
Range 0.00 to 10.0%
Resolution 0.01% for salt concentration of 0.00 to 2.99%
0.1% for salt concentration of 3.0 to 10.0%
Accuracy Displayed value ± 0.05% (for salt concentration of 0.00 to 0.99%)
Relative precision ± less than 5% (for salt concentration of 1.00 to 10.0%)
Ambient Temperature 10 to 40°C (Automatic Temperature Compensation)
Power Supply 006P Dry battery (9V)
Dimensions & Weight 17×9×4cm, 220g
(Main Unit only)

· NaCl Solution 2.50% (±0.05%) AB250 [*1] : RE-120250

ES-421

Digital salt-meter ES-421

Close

Dried fish Salt-meter PAL-FM1

The PAL-FM1 features convenient operation of direct measuring of salt in dried fish by the probe. It only takes 3 seconds to measure. However, measurements at different locations may be inconsistent, and such direct measurements may vary from measurements by dilution methods.

Specifications
Model PAL-FM1
Cat.No. 4221
Scale Dried fish salt %
Range 0.0~10.0%
(Automatic Temperature Compensation)
Resolution 0.1%
Power Supply 2 × AAA Batteries
International Protection Class IP65 Water resistant
Dimensions & Weight Main Unit:55(W)×31(D)×109(H)mm
Electrode probe : Φ15×570mm (Cable length : applox.400mm)

· Battery Case Cover With O-Ring : RE-38163

· USB Battery Charger : RE-34801

PAL-FM1

Dried fish Salt-meter PAL-FM1

Close

Digital Hand-held “Pocket” Salt-meter PAL-SALT PROBE

The PAL-SALT PROBE features convenient operation of submerging the probe in a liquid for measuring the salt content in as fast as 3 seconds. The probe may be inserted directly into semi-solid food. However,measurements at different locations may be inconsistent,and such direct measurements may vary from measurements by dilution methods.
・Electrode pins have extended from 5mm to 10mm for easier measurement.
・Screen now features a backlight for an easier to read

Specifications
Model PAL-SALT PROBE
Cat.No. 4222
Scale Salt concentration (g/100g)
Method Conductivity method
Range 0.00 to 7.0%
Resolution 0.01% (0.00 to 1.99%)
0.1% (2.0 to 7.0%)
Accuracy ± 0.1% (0.00 to 1.99%)
Relative precision : ± 5% (2.1 to 5.0%)
Relative precision : ± 10% (5.1 to 7.0%)
Temperature compensation 5 to 40 ゚C
Power Supply 2 × AAA Batteries
International Protection Class IP65 Water resistant
Dimensions & Weight Main Unit : 55(W)×31(D)×109(H)mm, 100g
Electrode probe : Φ15×570mm (Cable length : applox.400mm)

· Battery Case Cover With O-Ring : RE-38163

· USB Battery Charger : RE-34801

PAL-SALT PROBE

Digital Hand-held “Pocket” Salt-meter PAL-SALT PROBE

Close

"Pocket" Salt-meter PAL-Easy SALT

Professional salinity meter that can easily control salinity with high accuracy. It is the only titanium electrode in the world and durability is outstanding.

Specifications
Model PAL-Easy SALT
Cat.No. 4101
Range Sodium Chloride:0.0 to 10.0%
Minimum Indication 0.01% (up to 2.99% salt)
0.1% (above 3.00% salt)
Accuracy ±0.05% (up to 0.99%)
Relative precision of ±5% (above 1.00%)
Temperature compensation 5 to 100°C

· Battery Case Cover With O-Ring : RE-38047

· USB Battery Charger : RE-34801

PAL-Easy SALT

"Pocket" Salt-meter PAL-Easy SALT

Close

Seawater meter PAL-Fish Tank

This model is for measuring the salinity in seawater.
The only one model in the world adopt the titanium as an electrode.
It is resistant to scratches and has much durability.

Specifications
Model PAL-Fish Tank
Cat.No. 4121
Range Salinity:0.0 to 45.0‰
Minimum Scale 0.1‰
Accuracy ±2.0‰
Sample Volume 2 to 3 drops
Measurement Time About 3 seconds
Power Supply 2 × AAA Batteries
Battery Life About 11,000 measurements (When using AAA Batteries. About 1,500 times for PAL-S only)
International Protection Class IP65 Water resistant
Dimensions & Weight 5.5 × 3.1 × 10.9cm 100g (main unit only)

· Battery Case Cover With O-Ring : RE-38047

· USB Battery Charger : RE-34801

PAL-Fish Tank

Seawater meter PAL-Fish Tank

Close

PAL-Easy SALT & DPH-2 Koi Meister Set

It is a set that can measure "salinity" and "pH" which are important for a carp.

Specifications
Model Koi Meister Set
Cat.No. 4020
Range Salinity: 0.00 to 10.0%
pH: 0.0 to 14.0pH
Minimum Indication Salinity :
0.01%(0.00 to 2.99%)
0.1%(3.0 to 10.0%) 
pH :0.1pH
Accuracy Salinity:
±0.05%(0.00 to 0.99%)
Relative accuracy:±5%(1.00 to 10.0%) 
pH:±0.1pH(2.0~12.0pH)
Koi Meister Set

PAL-Easy SALT & DPH-2 Koi Meister Set

Close