Detects blend ratios in real time and provides feedback to prevent non-conforming products.
Performs a final check to ensure the product is within specifications before filling. It can also be used to reduce liquid loss by managing the switchover to water during cleaning.
Knowing the Brix of the extracted liquid allows you to manage the extraction rate. Depending on the extraction rate, re-extraction may be performed.
Continuously confirms that the concentration is within specifications. Inline measurement is a full-volume inspection.
Contamination with cleaning solution (water) /
Detect concentration changes in real time to identify nonconformities
Human error with batch measurement
Human error is impossible with full-volume automatic measurement
Defects in raw materials or upstream processes
Block nonconformities within each process by introducing equipment for each process
Nonconformities with unknown causes
Data storage allows for cause investigation
A hybrid refractometer and electrical conductivity meter.
With a measurement range of 0.0 to 93.0% Brix and 0.00 to 15.00% saline concentration,
it enables automatic in-line concentration and salinity management.
No residual cleaning solution
Remaining cleaning solution
This function determines whether cleaning solution used in CIP remains in the pipes.
By pre-setting the concentration (Brix) and saline concentration (Salt) thresholds, the LCD and lamp indicate whether there is cleaning solution.
Preventing contamination leads to improved product quality and optimized production processes.
*CM-BX|SALTα only
The base unit is Brix, but an offset function is installed to allow for actual concentration management.
Depending on the type of cutting oil, the actual concentration may differ from the displayed value.
You can display the actual concentration by setting a conversion factor and adjusting the measurement value.
*CM-BASEα Brix scale only
Measures a wide range from 0.00 to 80.0% Brix with high accuracy of ±0.1%. A wide range of dedicated scales and an intrinsically safe explosion-proof model meet various needs.
Equipped with a DC 4mA to 20mA current output function for use with a recorder. Equipped with RS-232C data output for PC use.
Equipped with an automatic temperature compensation function, it can handle a wide temperature range from 5°C to 100°C. The wetted surface can withstand temperatures up to 160°C, allowing for safe CIP and SIP cleaning.
We offer customized wetted surfaces for measuring chemical samples. The standard stainless steel specification can be upgraded to Hastelloy or titanium. Because all metals are machined and polished in-house, we are flexible in accommodating material changes.
Our commitment to long-term use leads to high durability and a low failure rate. In the unlikely event of repair, we will respond promptly and courteously.
If you are able to provide your own wiring and power, there is no additional installation fee. If you have any concerns, please contact us for a consultation.
The product meets the surface finish level Ra 0.8 or less required by the EHEDG and 3-A Sanitary Standards for wetted parts, and also meets the stainless steel composition requirements stipulated in EC No. 1935/2004 and FDA (21 CFR)-GRAS (Generally Recognized as Safe).
The previous π-type piping has been eliminated, and the shape of the original straight and L-type sample introduction sections has been improved. This eliminates liquid accumulation and improves replacement performance, thereby improving temperature detection capabilities.
For situations where adhesion to the prism surface is unavoidable due to the nature of the sample liquid during long measurements, we offer the US-α/Prism Wiper Anti-Adhesion Ultrasonic Device.
Eliminates the need to stop the line or repeatedly remove the in-line refractometer to clean the prism surface.
Lineup
Learn MoreCustom-made inline wetted parts materials available
We offer customized wetted surfaces for measuring chemical samples. The standard stainless steel specification can be upgraded to Hastelloy or titanium. Because all metals are machined and polished in-house, we are flexible in accommodating material changes.
SUS (standard specification)
Stainless steel with high strength and excellent corrosion resistance. Sanitary specification.
Titanium
A metal that is strong, lightweight, corrosion-resistant, and heat-resistant. It is more corrosion-resistant than stainless steel, especially to salt.
Hastelloy
An alloy with high corrosion and heat resistance. It is particularly resistant to hydrochloric acid and sulfuric acid, and its corrosion resistance is not easily compromised even at high temperatures.
We also offer piping that complies with the Varivent standard.
Please contact us for details.
What is VARIVENT®?
VARIVENT® is a standard for piping installation. It is primarily used in Europe. It can be installed by adjusting the dimensions of the piping installation to comply with the Varivent standard. The PRM series and CM series also offer piping that complies with the Varivent standard. * VARIVENT® is a registered trademark of GEA Process Engineering, Inc.
Salt Water
CM-BASEα-03S
Specific gravity of salt water
CM-BASEα-04S
Baume scale of salt water
CM-BASEα-05S
Concentration of seawater
CM-BASEα-06S
Specific gravity of seawater
CM-BASEα-07S
Baume scale of seawater
CM-BASEα-08S
Soy milk
CM-BASEα-27S
Citric acid
CM-BASEα-29S
Acetic acid
CM-BASEα-30S
Formic acid
CM-BASEα-31S
DMF
CM-BASEα-38S
Hydrogen peroxide solution
CM-BASEα-39S
Sodium hydroxide
CM-BASEα-40S
Magnesium chloride
CM-BASEα-43S
Propylene glycol
CM-BASEα-88S
Propylene glycol
CM-BASEα-89S
Cutting oil
CM-BASEα-101S
Potassium hydroxide
CM-BASEα-121S
Urea solution
CM-BASEα-Urea
Dampening solution
CM-BASEα-DampeningWater
Inline Meter Guide